Go

Model 6432e

    

   

  

Point-of-Use Ionizing Blower

Simco-Ion’s Point-of-Use Ionizing Blower Model 6432e controls static discharge in assembly, inspection and packaging areas. The Model 6432e can also be used in-tool to control static build-up problems such as product contamination, material mishandling or microprocessor lock-up.

  • IsoStat Technology
  • 24 VDC or 24 VAC input power
  • Small footprint design with benchtop or in-tool mounting stand
  • Facility Monitoring System (FMS) interface
  • Operational failure alarm

 


For additional information on the 6432e Blower or other ionization solutions for static control and particle contamination control, contact Sales Services.

Specifications

Input Voltage 24 VDC (±10%) or 24 VAC (±10%), 50-60 Hz, 6W max
Discharge 24 VAC Input:  <4 sec @ 12” (30.5 cm); ±1000-100V
24 VDC Input:  <5 sec @ 12” (30.5 cm); ±1000-100V
Balance ±20V @ 12” (30.5 cm) away
Cleanroom Class ISO 14644-1 Class 5
Dimensions 5.28”H x 5.19”W x 2.49”D (13.4 x 13.1 x 6.32 cm) without stand
Weight 1.31 lb (0.59 kg) with benchtop stand
  • Transformers
  • Wall Outlet Connector
  • AC/DC Adaptor

 

 

ANSI/ESDA SP3.4-2016 – Protection of Electrostatic Discharge Susceptible Items – Periodic Verification of Air Ionizer Performance Using a Small Fixture – products designed for confine space.

Please refer to all the applicable industry standards for comprehensive electrostatic charge management on our Industry Standards page.

Target Markets

  • Electronics Assembly
  • Life Sciences
  • Back-End Semiconductor Processing

Target Applications

Model 6432e Point-of-Use Ionizing Blower controls static along parts and a workstation.

Model 6422e Point of Use Ionizing Blower controls static along a electronic conveyor test station

Contact us