4612 Ionizer

 4612 In-tool Ionization System with Controller for Extreme Environments

Eliminates Static Charge in Hard to Control Extreme Environments

Simco-Ion’s new Extreme Temperature Ionization System provides <±5V balance in extreme environments from -50°C to +155°C.  The 4612 Ionizer, along with its 4062e-CLC Controller and 550 Extreme Temperature Antenna use closed-loop control to ensure the ionizer’s output is balanced at the location that’s critical.   

  • Operates in temperatures as high as 155°C (310°F) and as low as -50°C (-58°F)
  • Balance control of better than ±5V standard meets the new stringent requirements for S20.20
  • Antenna to measure balance at the device location


Download Datasheet

Model 4612 datasheet


For additional information on the 4612 ionizer or other ionization solutions for static control and particle contamination control, contact Sales Services.


Specifications

Balance <±5V when used with 4062e-CLC Controller and 550 Antenna
Stability <±10V (30 day average) when used with 4062e-CLC Controller & 550 Antenna
Discharge <2 sec @ 150 mm; <5 sec @ 300 mm, with 0.3m/sec laminar air flow
Airflow 0.2-0.45m/sec laminar airflow (30-90 fpm)
Dimension 210L or 526L x 21W x 30H mm (8.3 or 20.7L x 0.8W x 1.2H in)
Weight 100 g (4612-210); 250 g (4612-526) (0.2 or 0.6 lb)
  • High Voltage Connector Kit
  • Emitter Point Extenders
  • Silicon Emitter Points

Target Markets

  • Back-end Semiconductor Manufacturing 

Target Applications

The back-end semiconductor industry uses a series of extensive reliability testing that will ensure the conformance of integrated chips and modules. Testing of the product at extreme high and low temperatures is designed to accelerate real life conditions where the product will be used. The High Temperature 4610 Ionizer System is perfect for the extreme environment where that type of reliability testing occurs.